Ground fire hydrant
Surface fire hydrant (H1350, H1750, H2150) is an emergency support in accordance with EN 14384, EN 1...
Standard; EN 124-2 ; ГOST 3634-2019
Body size; 785х740 mm
Opening diameter of the passage; 600 mm
Body height; 100 mm
Regulatory load; 900 kN
Weight; 86,62 kg
Material: high-resistance spherical graphite cast iron GGG50
DETAIL | QUANTITY |
Body |
1 |
Cover |
1 |
Locking system |
1 |
T-rubber |
1 |
Bolt |
1 |
Pin |
1 |
Nut |
1 |
Passport |
1 |
*It is allowed to prepare 1 passport for a group of manhole covers of not more than 10 pieces. |
Surface fire hydrant (H1350, H1750, H2150) is an emergency support in accordance with EN 14384, EN 1...
It is used for the evacuation of the water collected at the roads used by pedestrians, light and hea...
Waste box is used for waste disposal purposes in parks, parking lots, airports, stations, etc.